Kato Syncro

General Details
Chain operated electrical actuator with double row four link articulated
chain contained in composite casing designed for the movement
of outward opening windows, transom windows, domes and
dormer windows. See Technical Data table for specifications. The
actuator has a traction and thrust capacity of 300 N, and has been
designed to function both at a voltage of 230V AC 50Hz or at low
voltage of 24V DC. The device has been equipped with a universal
swing support that can be assembled rapidly without screws
(patented), with clevis for outward opening windows and special
socket for transom windows (patented). Limit switch: electronic
with four (4) track runs (100 – 200 – 300 – 400 mm), which can be
selected at any time by means of a dip-switch; at current absorption
at closure and as protection against overloading. Can be connected
in parallel and complies with Directives 2004/108 CE (EMC
Directive) and subsequent amendments and 2006/95 CE (Low
Voltage Directive) and subsequent amendments.
Standard colours: BLACK (circa RAL9004), WHITE (circa
RAL9003), and GREY (circa RAL7047).

Technical Details
MODEL KATO 230 KATO 24 SYNCRO 230 SYNCRO 24 RADIO 230
Pressure and traction force 300 N 300 N 300 N 300 N 300 N
Track runs (can be selected at any time) 110, 200, 300, 400 mm 100, 200, 300, 400 mm
Voltage 230V AC 50 Hz 24V DC 230V AC 50 Hz 24V DC 230V AC 50 Hz
Current consumption at nominal charge 0,115 A 0,950 A 0,115 A 0,950 A 0,115 A
Charge absorbed at nominal load ~ 25W ~ 23W ~ 25W ~ 25W ~ 25W
No load speed 12,5 mm/s 12,5 mm/s 8,5 mm/s 8,5 mm/s 9,5 mm/s
No load duration (400 mm) 32 s 32 s 48 s 48 s 43 s
Double electrical insulation YES Low Tension YES Low Tension YES
Type of service S2 di 3 min
Working temperature – 5 + 65 ºC
Protection index IP30
Adjustment of socket at casing Position self regulating
Connection of two or more devices in parallel YES YES YES YES NO
Limit switch stop at opening Electronic with regulation by means of dip-switch
Limit switch stop at closure At absorption of power
Protection on overload at opening and closure At absorption of power
Dimensions mm 386,5x59x37
Weight kg 0,970 0,940 1,180 1,150 1,130